Downloads - Nuclear Measurements

Multi Channel Analyzer: User Programs

WinSPEC - Version 2.10.0005

Release Notes

WinSPEC is one of the basic programs to work with the MCA166 and the MCA527 Series.

This setup contains the both variants WinSPEC for Inspectors und WinSPEC for Automation.

Note: We have changed to the setup file format to *.msi. If a version of WinSPEC is on your computer, that has been installed with the previous setup file format, it is recommended to deinstall it before.

Size: 7 MB

WinMCS - Version 2.05.0004

Release Notes

WinMCS is one of the basic programs to work with the MCA166 and the MCA527 Series.

This setup contains the both variants WinMCS for Inspectors und WinMCS for Automation.

Note: We have changed to the setup file format to *.msi. If a version of WinMCS is on your computer, that has been installed with the previous setup file format, it is recommended to deinstall it before.

Size: 6 MB

WinSCAN - Version 2.07.0005

Release Notes

WinSCAN measures max. 2000 single MCA spectra and assembles a MCS spectrum from it. The measurement is saved in one *.spe file.

Size: 5 MB

WinU235 - Version 2.02.0001

Release Notes

Program for U235 enrichment measurements with NaI-detectors.

Size: 5 MB

WinUF6 - Version 2.02.0001

Release Notes

WinUF6 allows enrichment measurements on UF6 - cylinders with HPGe-Detectors.

Size: 5 MB

WinTimestamps - Version 1.03.0001

Release Notes

WinTimestamps allows to use the MCA-527 as timestamps recorder (list mode).

Size: 4 MB

MCA-527 Transient Recorder - Version 1.01.0000

The program allows to use the MCA-527 as an transient recorder independently from other applications.

Size: 1 MB

MCA-527 Oscilloscope - Version 1.08.0004

Important hints

The program allows to use the MCA-527 as an oscilloscope independently from other applications.

Size: 2 MB

Identify Demo Version

Release Notes for the licensed program

Datasheet

Hints for Windows 7

Program for nuclide identification from gamma spectra. Identify is also as OEM version available. Please do not hesitate to contact us if you have any further questions..

Size: 4 MB

MCA Wand - Version 1.9

MCA Wand is a file converter, which supports different file types (from spe, chn, spc to spe, chn, dat).

Features:

  • Multi File Converting
  • Preview of spectra files
Size: 1 MB

R6a - Version 5.0

Program for the calculation of the transmission of x-rays and gamma-rays.

Size: 3 MB

Multi Channel Analyzer: Tools

MCA-527 IP Tool - Version 1.00.0003

The program allows to set a fixed IP address on MCA-527.

Size: 1 MB

MCA-527 RS485 Configurator - Version 1.00.0003

Release Notes

The MCA-527 RS485 Configurator allows to configure the RS485 interface of the MCA-527 for the intended operating conditions.

Size: 1 MB

MCA-527 Basic State Configurator - Version 2.00.0000

The MCA-527 Basic State Configurator is intended for detector manufacturers who integrate the MCA-527 Micro, Nano or OEM within the detector encasement or for technicians who construct systems with permanently connected detector.
The tool allows to predefine the basic state of the MCA-527 (firmware version 21.00 or higher). The basic state is stored in the EEPROM and is established during power-up or during reset.

Before using this tool, the most suitable parameters for the detector have to be determined with any qualified program (e.g. WinSPEC). After that the parameters can be taken over by this tool.

Size: 2 MB

MCA-527 Power Module Reconfigurator - Version 1.00.0001

The MCA-527 Power Module Reconfigurator allows to reconfigurate the maximum adjustable high voltage  of the MCA-527 power module (full und lite version) to 5000V.

By default, the high voltage is limited to 3600V. Users who want to use a 5000V high voltage module have to increase the maximum adjustable high voltage with this program.

Size: 44 kB

Multi Channel Analyzer: Drivers

USB Device Driver 32bit - Version 2.12.28

The device driver is needed for MCA-166 USB, MCA-527 and NScan. If you want to run the devices with self-developed applications, you have to install the device driver with this installation program. The installation programs for applications developed by us already include the installation of the device driver.

Run the installation program before you plug in the device.

Size: 2 MB

USB Device Driver 64bit - Version 2.12.28

The device driver is needed for MCA-166 USB, MCA-527 and NScan. If you want to run the devices with self-developed applications, you have to install the device driver with this installation program. The installation programs for applications developed by us already include the installation of the device driver.

Run the installation program before you plug in the device.

Size: 2 MB

Multi Channel Analyzer: Firmware

How to upload the MCA-527 firmware

You can find the firmware for newer hardware versions on this website. If you have an MCA527 with an older hardware version, please contact us personally.

Size: 1 kB

GBS Firmware Loader Version 1.03.0001

The GBS Firmware Loader allows uploading the following firmware to the corresponding unit type.

Size: 76 kB

Firmware V.24.00 for MCA-527 Full Version (HW 23.00*)

*The hardware version is displayed in the "Diagnostics" dialog of the programs for the MCA.

Size: 598 kB

Firmware V.24.00 for MCA-527 V (Lite) Version (HW 23.00*)

*The hardware version is displayed in the "Diagnostics" dialog of the programs for the MCA.

Size: 82 kB

Firmware V.24.01 for MCA-527 OEM Version (HW 23.00*)

*The hardware version is displayed in the "Diagnostics" dialog of the programs for the MCA.

Size: 599 kB

Firmware V.24.01 for MCA-527 Micro Version (HW 23.00*)

*The hardware version is displayed in the "Diagnostics" dialog of the programs for the MCA.

Size: 577 kB

Firmware V.24.01 for MCA-527 MicroE Version (HW 23.01*)

*The hardware version is displayed in the "Diagnostics" dialog of the programs for the MCA.

Size: 581 kB

Firmware V.24.00 for MCA-527 Nano Version (HW 23.00*)

*The hardware version is displayed in the "Diagnostics" dialog of the programs for the MCA.

Size: 578 kB

Multi Channel Analyzer: Libraries / Example Code

MS Windows MCA communication library - Version 2.16.0001

The MCA communication library provides functions that can be used by MCA-166 or MCA-527 users for developing their own MS Windows applications. The functions are described in the User's Manuals for the MCA-166 and MCA-527.

Size: 1 MB

Linux MCA communication library and command line tool - Version 1.2.0

This package provides the C++ source code of an MCA communication library with essential basic functions similar to the Windows communication DLL. Further it contains a simple command line tool to communicate with an MCA. The software uses the FTD2XX library which is based on an unmodified version of libusb. It is intended for Linux systems. Documentation is included.

Size: 137 kB

Example code: Reading of list mode 4 data from *.mca files

This example code can be used for developing an own application that needs to read list mode 4 data from a *.mca file.

Size: 41 kB

Multi Channel Analyzer: Developer Information

MCA527 Firmware Commands

Description of the MCA527 firmware commands (2024-07-04)

Size: 669 kB

Windows MCA Communication DLL

Description of the MCA Communication DLL (2024-07-04)

Size: 359 kB

Linux MCA Communication Library

Description of the MCA communication library which is available as source code for Linux systems (2022-05-10)

Size: 53 kB

MCA Spectral Data Format

MCA Spectral Data Format (2018-09-21)

Size: 177 kB

MCA527 Binary Data Format

MCA Binary Data Format (2021-09-20)

Size: 239 kB

MCA527 Serial Interface

Description of the MCA527 serial Interface, especially within bussystems

Size: 130 kB

MCA User Data memory

Use of the MCA User Data Memory by Specific Applications (2012-10-30)

Size: 127 kB

Quick IDENTIFY User Manual

Quick IDENTIFY is a function library that third-party providers can integrate into their software.

Size: 518 kB

Linux command line tool GBS_MCA_Cmd

GBS_MCA_Cmd is a simple command line tool to communicate with an MCA-527 or MCA-166 under Linux systems. User information (2022-05-10)

Size: 57 kB

Multi Channel Analyzer: Datasheets

Multi Channel Analyzer: User Manuals and Additional Documents

Size: 2 MB

Size: 2 MB

MCA527 Setup

How to do a optimum setup fo MCA527

Size: 550 kB

MCA527 Setup Short Version

How to do a MCA527 Setup (Short Version)

Size: 22 kB

MCA527 Oscilloscope

Description of the MCA527 Oscilloscope Mode (2013-09-12)

Size: 164 kB

MCA527 Series List Mode Option

Explanations of the list modes

Size: 206 kB

Multi Channel Analyzer: Accessories

Size: 349 kB

Size: 335 kB

Size: 140 kB

Detectors: Datasheets

Special Equipment: Datasheets

Size: 1 MB

Size: 239 kB

References of GBS Elektronik GmbH

Research Center Dresden-Rossendorf | Technical University of Berlin | University of Frankfurt | Society of Heavy Ion Research, Darmstadt | University of Augsburg | Institute for Surface Modification, Leipzig | Research Center Jülich | European Commission, Luxembourg | Institute for Reference Materials and Measurements, Geel, Belgium | Joint Research Center Ispra, Italy | Instituto Nacional de Pesquisas Espaciais, Brazil | CNEA, Argentina | National Accelerator Center, Cape Town, South Africa | Samsung, South Korea | University of Sydney, Australia